CCSKW - JUMBO SHEATHING FIRE-SHIELD

  • MSDS: CCSKW
  • Manufacturer: NATIONAL GYPSUM CO
  • Product Name: JUMBO SHEATHING FIRE-SHIELD
  • National Stock Number: 5640-00N074912
Product Identification

Product ID:JUMBO SHEATHING FIRE-SHIELD
MSDS Date:07/27/1994
FSC:5640
NIIN:00N074912
MSDS Number: CCSKW

Responsible Party
NATIONAL GYPSUM CO
2001 REXFORD RD
CHARLOTTE, NC 28211
US

Emergency Phone: 704-365-7543

Info Phone: 704-365-7543

Preparer: NORBERT W KALETA

Cage: 85074

Contractor
NATIONAL GYPSUM CO
CHARLOTTE, NC 28211-3415 US

Telephone: 704-365-7300

Cage: 85074

Ingredients

2); (GYPSUM)

CAS: 10101-41-4

RTECS: EW4150000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


SILICA, CRYSTALLINE - QUARTZ; (QUARTZ)

CAS: 14808-60-7

RTECS: VV7330000

OSHA PEL SEE TABLE Z-3

ACGIH TLV: 0.1 MG/M3 RDUST


CELLULOSE (PAPER FIBER)

CAS: 9004-34-6

RTECS: FJ5691460

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: GOLD BOND BOARD PRODS DO NOT
PRESENT INHAL, INGEST/CONT HLTH HAZ UNLESS SUBJECTED TO OPERATIONS
SUCH AS SAWING, SANDING/MACHINING WHICH RSLT IN GENERATION OF
AIRBORNE PARTICULATE. SKIN: CONTINU ED & PRLNG CONT MAY RSLT IN DRY
SKIN. EYE: DIRECT CONT MAY CAUSE MECH IRRIT. INHAL: TARGET ORGAN:
RESP SYS.
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-QUARTZ: IARC
MONOGRAPHS, SUPPLEMENT, VOL 7, PG 341, 1987: GROUP 2A. NTP 7TH
ANNUAL REPORT (SUP DAT)
Effects of Overexposure:CONTINUED AND PROLONGED EXPOSURE TO AIRBORNE
DUST CONCENTRATIONS IN EXCESS OF THE PEL/TLV MAY RESULT IN COUGH,
DYSPNEA, WHEEZING, AND IMPAIRED PULMONARY FUNCTION.
Medical Cond Aggravated by Exposure:OVEREXPOSURE WOULD GENERALLY
AGGRAVATE RESPIRATORY SYSTEM DYSFUNCTIONS.

First Aid

First Aid:EYES: IMMEDIATELY FLUSH WITH WATER FOR AT LEAST 15 MINUTES
AND GET MEDICAL ATTENTION. SKIN: FLUSH AND WASH SKIN WITH SOAP AND
WATER. GET MEDICAL ATTENTION IF IRRITATION PERSISTS. INHALATION:
MOVE THE EXPOSED PERSON TO FRESH AIR AT ONCE. IFNOT BREATHING
INITIATE PULMONARY RESUSCITATION. GET MEDICAL ATTENTION. INGESTION:
CALL MD IMMEDIATELY .

Fire Fighting

Flash Point:NOT COMBUSTIBLE
Extinguishing Media:DRY CHEMICAL, FOAM, WATER FOG OR SPRAY.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:PICKUP TO AVOID TRIPPING HAZARD.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP DRY TO PRESERVE USEFULNESS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:A NIOSH APPROVED RESPIRATOR FOR TOXIC DUSTS IS
RECOMMENDED IF THE PEL/TLV IS EXCEEDED.
Ventilation:PROVIDE VENTILATION TO MAINTAIN A DUST LEVEL BELOW THE
PEL/TLV.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:THE SCORE AND SNAP METHOD OF CUTTING IS
RECOMMENDED. SAWING, DRILLING OR MACHINING WILL PRODUCE DUST.
Supplemental Safety and Health
EXPLAN OF CARCIN: ON CARCINOGENS, 1994: ANTICIPATED TO BE CARCINOGEN.
ANIMAL: LUNG.

Chemical Properties

Appearance and Odor:GYPSUM CORE WRAPPED W/PAPER. SURFACE FINISH WILL
VARY W/PROD. NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:WHEN HEATED TO DECOMPOSITION, OXIDES
OF SULFUR AND CARBON WILL BE RELEASED.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH APPLICABLE LOCAL,
STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.